ON BOARD, IN-USE VEHICLE EMISSIONS ANALYZER
SYSTEM SPECIFICATIONS:
| |
Range |
Resolution |
Accuracy |
| CO2 |
0 - 20% |
.01% |
±
0.1% or
± 3% of reading |
| CO |
0 - 8% |
10 ppm |
±
50 ppm or
± 3% of reading |
| 0 - 8% |
.001% |
±
3% or
± 0.02% of reading |
| THC |
0 - 100 ppm |
0.1 ppm |
2 ppm or
± 1% of reading |
| 0 - 1,000 ppm |
1 ppm |
±5
ppm or
± 1% of reading |
| 0 - 40,000 ppm |
1 ppm |
±10
ppm or
± 1% of reading |
| NO |
0 - 2,500 ppm |
1 ppm |
±15
ppm or
± 3% of reading |
| NO2 |
0 - 500 ppm |
1 ppm |
±10
ppm or
± 3% of reading |
| Warm-up time: |
60 minutes |
| Sample flow rate: |
8 LPM |
| Ambient operating temperature: |
2° to 40° C |
| Storage temperature: |
-10° to 60° C |
| Data capture rate: |
≥ 1 Hz |
Specifications are
subject to change without notice. While due caution has been exercised in the
production of this web site, possible errors and omissions are unintentional.
SYSTEM FEATURES:
-
Portable or 19" rack mount configuration
-
Sample system maintained at 200°
C
-
Auto-ranging, heated FID
for THC analysis
-
CO and CO2
measurements using NDIR spectroscopy
-
Pentium P5 CPU for
high-speed data capture and processing, precise system control and external
communications capability
-
Simultaneous NO and NO2 measurements using NDUV
-
Up to 1 GB Compact
Flash data storage capacity (over 300 hrs of testing)
-
LabVIEW™
User Interface
-
Message Center for the
display of instrument status, operating condition, fault diagnostics and
remote communications status
-
Wireless Communication
-
Weather Probe
-
Sensor-Tech Software
SYSTEM OPTIONS:
-
Global Positioning System
(GPS)
-
J1587/1708, J1850/1979 and
J1939/J2284 vehicle data stream recording and display capability
-
PDA Software
-
80A portable power supply
-
240V/120V/12V rack mount
power supply
-
Mobile cart for test cell
applications
SELECTED FOR USE BY THE US
EPA |