2" Diameter |
2.5" Diameter |
3" Diameter |
4" Diameter |
5" Diameter |
|
Recommended Vehicle Application |
LD Gasoline < 2 liters |
LD Gasoline
2 - 5 liters |
LD Gasoline >5 liters |
HD Diesel
6 - 12 liters |
HD Diesel
12 - 18 liters |
LD Diesel
< 1.5 liters |
LD Diesel
1.5 - 4 liters |
LD Diesel
4 - 6 liters |
|
| Flowrate1
at backpressure of 10" H20 (2000 C) |
175 SCFM |
425 SCFM |
600 SCFM |
1100 SCFM |
1700 SCFM |
| Flowrate1
at backpressure of 15" H20 (2000
C) |
215 SCFM |
550 SCFM |
775 SCFM |
1350
SCFM |
2100 SCFM |
| Exhaust Temperature Range |
Ambient to 5500
C |
| Linearity2 |
Better than 1% full scale |
| Cycle Accuracy |
Better than
± 3 % |
| Resolution |
0.1 SCFM |
| Noise2
at typical idle flowrates |
0.1 SCFM at 5 SCFM flowrate |
| Warm Up time |
5 minutes |
| Response time |
T90
< 1 second |
| Data Rate |
Up to 4 Hz |
| Power Requirements |
12 VDC, < 50 W |
| Communications |
RS-232, CAN |
| Flow tube length |
18" |
22.5" |
27" |
28" |
35" |
| Flow tube weight |
3.2 lbs |
4.5 lbs |
5.9 lbs |
7.0 lbs |
12.2 lbs |
| Electronic Module Dimensions |
10 1/4" L x 6 3/8" W x 4" H |
| Electronics Module Weight |
8.4 lbs |
1 Higher flows can be
measured, but at higher backpressures.
2 As determined from NIST
traceable LFE flow stand.
TECHNOLOGY LICENSED FROM THE US
EPA
Total exhaust flow, as measured by SEMTECH EFM, is a critical
component of EPA's "ROVER" mass emissions measurement technology,
described in U.S. Patent #6, 148, 656. Sensors, Inc., an exclusive
co-licensee of this technology, has developed the EFM to complement its
on-vehicle SEMTECH-D and G analytical systems, thereby providing users
with the most precise in-use mass measurements capability currently
available. Specifications are subject to change without notice.
While due caution has been exercised in the production of this web site,
possible errors and omissions are unintentional. |