Stationary FID
The FID 3001W measures total hydrocarbons in a wide range of applications, such as catalytic and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Designed with a hinged housing, the FID 3001W is easy to install and access. The wall mounted analyzer is compact, robust and weather proof.

 

  • Features
  • Specifications
  • Options
  • Resources
  • Built-in, titanium, heated sample gas filter
  • Heated to 200°C, or 300°C option
  • Filter monitoring
  • Automatic flame ignition
  • Hydrogen cut-off

Measuring component: CxHy
Display: 6 digit LED
Decadic measuring range: 5
Smallest measuring range: 0 - 10 ppm
Largest measuring range: 0 - 100.000 ppm
Range selection: manual
Repeatability: ±1% of reading
Instrument zero drift: ±1% in 24 hr
Response time: T90 < 1.0 second
Warm-up time: approx. 30 minutes
Analog output:: 0 - 20 mA or 4 - 20 mA
Power supply: 115V / 60 - 50 Hz
Power consumption: 300 W
Ambient temperature: 0 - 45°C
Size (H x W x D): 325mm x 600mm x 465mm
Weight: 36 kg
Gas Requirements
Fuel: H2, 5.0
Fuel consumption: approx. 35 ml/min
Span gas: C3H8
Span gas consumption: 1 l/min
Zero gas: N2, 5.0 or synth. air
Zero gas consumption: 1 l/min
Combustion air: charcoal cartridge
Combustion air consumption: 30 l/hr